Environmental

 
Extech SD700 Humidity Dataloggers - Max Temperature: 122 F, Min Temperature: 32 F
  • Max Temperature: 122 F (50 CWhat's This?)
  • Min Temperature: 32 F
  • Power Source: AC Line, Battery
  • Input Source (Probe): Internal Probe
  • SAMPLE RATE/Intervals: 5, 10, 30, 60, 120, 300, 600 seconds
  • Accuracy: ±1.5°F (0.8°C)

List Price: $340.99

Your Price: $303.48

Sign-in for EDU Pricing!

In Stock:
  • Free shipping over $99
  • View Payment Options
Extech SD500 Humidity Dataloggers - Max Temperature: 122 F, Min Temperature: 32 F
  • Max Temperature: 122 F (50 CWhat's This?)
  • Min Temperature: 32 F
  • Power Source: Battery
  • Input Source (Probe): Internal Probe
  • SAMPLE RATE/Intervals: 5, 10, 30, 60, 120, 300, 600 seconds or Auto
  • Accuracy: ±1.5°F ±4%RH

List Price: $268.99

Your Price: $239.40

Sign-in for EDU Pricing!

In Stock:
Extech 42280A - Temperature and Humidity Datalogger
  • Max Temperature: 158 F (70 CWhat's This?)
  • Min Temperature: -4 F
  • Power Source: Battery
  • SAMPLE RATE/Intervals: 30 sec, 5 min, 10 min, 30 min, 60 min, 90 min, 120
  • Accuracy: RH basic accuracy: ±3% Temperature basic accuracy: ±0.9°F (±0.5°C)
  • LCD Screen: Yes

List Price: $270.59

Your Price: $240.83

Sign-in for EDU Pricing!

In Stock:
Extech RHT20 Humidity Dataloggers - Max Temperature: 158 F, Min Temperature: -40 F
  • Max Temperature: 158 F (70 CWhat's This?)
  • Min Temperature: -40 F
  • Power Source: Battery
  • Input Source (Probe): Internal Probe
  • # Data Points: 16000
  • SAMPLE RATE/Intervals: 1 second to 24 hours

List Price: $157.99

Your Price: $140.61

Sign-in for EDU Pricing!

In Stock:
Extech 42275 Humidity Dataloggers - Max Temperature: 85 C, Min Temperature: -40 C
  • Max Temperature: 85 C
  • Min Temperature: -40 C (-40 FWhat's This?)
  • Power Source: Battery
  • Input Source (Probe): Internal Probe
  • # Data Points: 16000
  • SAMPLE RATE/Intervals: Programmable from 1 to 7200 seconds (2 hours)

List Price: $219.99

Your Price: $195.79

Sign-in for EDU Pricing!

In Stock:
Extech RHT10 Humidity Dataloggers - Max Temperature: 158 F, Min Temperature: -40 F
  • Max Temperature: 158 F (70 CWhat's This?)
  • Min Temperature: -40 F
  • Power Source: Battery
  • Input Source (Probe): Internal Probe
  • Accuracy: ±1.8°F (14 to 104°F) ±3.6°F (-40 to +14 and 104 to 158°F) ±3%RH
  • LCD Screen: No

List Price: $94.99

Your Price: $84.54

Sign-in for EDU Pricing!

In Stock:

Proposition 65 Warning

Extech 42270 Humidity Dataloggers - Max Temperature: 185 F, Min Temperature: -40 F
  • Max Temperature: 185 F (85 CWhat's This?)
  • Min Temperature: -40 F
  • Power Source: Battery
  • Battery Life: 1 YEARS (8760 HRWhat's This?)
  • # Data Points: 16000
  • # Inputs/Channels: 1

List Price: $138.59

Your Price: $123.35

Sign-in for EDU Pricing!

In Stock:
Extech 42280A-NIST - Temperature and Humidity Datalogger with Certificate of Calibration Traceable to NIST
  • Max Temperature: 158 F (70 CWhat's This?)
  • Min Temperature: -4 F
  • Power Source: Battery
  • SAMPLE RATE/Intervals: 30 sec, 5 min, 10 min, 30 min, 60 min, 90 min, 120
  • Accuracy: RH basic accuracy: ±3% Temperature basic accuracy: ±0.9°F (±0.5°C)
  • LCD Screen: Yes

List Price: $476.29

Your Price: $423.90

Sign-in for EDU Pricing!

In Stock:
General Tools CDM77535 - CO2 Handheld Digital Humidity and Temperature Meter
  • Max Temperature: 140 F (60 CWhat's This?)
  • Min Temperature: 14 F
  • Power Source: AC Line, Battery
  • Battery Life: 24 HR
  • Input Source (Probe): External Probe
  • # Data Points: 9600

List Price: $408.38

Your Price: $329.34

Sign-in for EDU Pricing!

In Stock:
General Tools DL8835 - Humidity Dataloggers - Max Temperature 185F
  • Max Temperature: 185 F (85 CWhat's This?)
  • Min Temperature: -40 F
  • # Data Points: 15999
  • SAMPLE RATE/Intervals: 1K/2K/4K/8K/16K
  • Accuracy: Temp.:+ 0.6oC(-20~50oC) , +1.2oC(-40~-20oC,51~85oC) o RH% +3% at 25 C
  • LCD Screen: Yes

List Price: $132.73

Your Price: $107.04

Sign-in for EDU Pricing!

In Stock:
General Tools DT4208SD - 12-Channel Thermocouple Thermometer with Excel-formatted Data Logging 3092 F
  • Type (Temperature): E, J, K, Other, S, T
  • Max Temperature: 3092 F (1700 CWhat's This?)
  • Min Temperature: -148 F
  • Power Source: AC Line
  • Accuracy: With Types K, J, T and E thermocouples:
    ± (0.4% of reading + 2.0ºF max)
    With Types R and S: ±(0.5% of reading + 2.0ºF)
  • LCD Screen: Yes

List Price: $1,020.00

Your Price: $822.58

Sign-in for EDU Pricing!

In Stock:
General DT4947SD - Data Logging 4 Channel Thermometer with SD Card, Max Temperature 3092°F
  • Type (Temperature): E, J, K, Other, S, T
  • Max Temperature: 3092 F (1700 CWhat's This?)
  • Min Temperature: -148 F
  • Power Source: AC Line
  • Accuracy: For Pt 100 ohm probes: ± (0.4% of reading + 1.8ºF)
    from -327º to 999.9ºF, ± (0.4% of reading + 2.0ºF)
    from 1000º to 1562ºF); for thermocouples:
    ± (0.4% of reading + 2.0ºF max)
  • LCD Screen: Yes

List Price: $306.30

Your Price: $247.01

Sign-in for EDU Pricing!